    Position首頁 > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
    LMC3-50 series RFID safety door switch

    1706678051308494.pngimage.png

    With detection confidentiality (unique code can be provided)

    ?Strong anti-interference, safety and reliability.

    ?Safety level PLe can be achieved by using safe dual-channel output technology.

    ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

    ?Can be used with the safety door.


    395181ccb7a771e30162f6415dc922a.png

    Ordering information

    86b9d0315b563dc534da6381bf695f3.png

    Switch model

    Specification

    Output method

    Encoding method

    LMC3-50-40SNT/5M


    4-core direct wiring with dual output
    5M cable


    NPN

    Universal encoding

    LMC3-50-40SN1/5M

    Unique encoding

    LMC3-50-40SPT/5M

    4-core direct wiring with dual output
    5M cable


    PNP

    Universal encoding

    LMC3-50-40SP1/5M

    Unique encoding

    LMC3-50-60JNT/5M

    6-core direct wiring with dual output and cascading 5M cable

    NPN

    Universal encoding

    LMC3-50-60JN1/5M

    Unique encoding

    LMC3-50-60JPT/5M

    6-core direct wiring with dual output and cascading 5M cable

    PNP

    Universal encoding

    LMC3-50-60JP1/5M

    Unique encoding

    395181ccb7a771e30162f6415dc922a.png

    Model Description


    395181ccb7a771e30162f6415dc922a.png

    Technical parameter

    Safty standard

    Mean Time to Dangerous Failure (MTTFd) (years)

    ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

    ≥30 years

    Safety classification

    Class 4 switch according to IS0 13849-1/suitable for PLe/PL

    Certification

    CE

    Horizontal working distance

    Conduction, min:10mm

    Vertical working distance

    Conduction, min:8mm

    Operating voltage

    24V DC±15%

    Operating current

    150mA

    Response time

    60ms

    The protection grades

    IP65, IP67 (customized)

    Operating frequency

    lHZ

    Working temperature

    -10~+55℃

    Relative humidity

    5%~95%

    Material

    Flame-retardant thermoplastic


    395181ccb7a771e30162f6415dc922a.png

    Shape and installation dimensions

    尺寸圖.pngLMC3-50.png


    395181ccb7a771e30162f6415dc922a.png

    Approach pattern of LMC3-50 switch

    1706679390304986.png1706679459242220.png


    395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


    Misalignment deviation

    breakover

    disconnect

    Alignment signal

    Horizontal alignment

    The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended

    Vertical alignment

    The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended


    395181ccb7a771e30162f6415dc922a.png

    Hookup

    Two-way output with cascade connection diagram

    serial number

    Signal definition

    colour

    explain

    1706680404188780.png

    1

    24V

    palm

    Power supply positive

    2

    0V

    blue

    Negative power supply

    3

    output1

    black

    Safety output 1

    4

    output2

    white

    Safety output 2

    5

    input1

    green

    Cascade input 1

    6

    input2

    yellow

    Cascade input 2


    395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


    接線圖.png



    395181ccb7a771e30162f6415dc922a.png

    RFID switch approach pattern

    Led display

    Signal state

    State description

    input

    output

    The red light is always on.

    Yes/No.

    break

    No actuator or incomplete alignment (universal coding)

    The red light is on for 1 second and then flashes twice (alternately).

    Yes/No.

    break

    No actuator or incomplete alignment (unique code)

    Red light flashing at 4Hz

    effective

    break

    Output overload

    Green light flashes at 1Hz.

    be invalid

    break

    No input signal (dual output is not applicable)

    The green light is always on

    effective

    through

    Induction is normal

    Alternate flashing of traffic lights

    effective

    break

    Label is not registered.


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  3. Click to refresh
  4. 主站蜘蛛池模板: 亚洲日韩精品秘在线观看| 伊在人亞洲香蕉精品區| 2020无码专区人妻系列日韩| 亚洲AV成人片不卡无码| av片网站| 国产精品免费jizzjizz| 亚洲国产成人精品激情| 中文乱码字慕人妻熟女人妻| 蜜臀av无码一区二区三区| 天堂av一区二区三区| 成人三级久久久久视频| 久久精品国产字幕高潮| 99re在线观看视频| 青青青伊人色综合久久| 91精品91| 国产精品186在线观看在线播放| 日韩精品自拍| 国精品99久9在线 | 免费| 麻豆视频在线| 青草午夜精品视频在线观看| 乱妇乱女熟妇熟女网站| 中国CHINA体内裑精亚洲日本| 国产女人十八毛片| 中文字幕 日韩 人妻 无码| 国产女人喷潮视频免费| 国产成人综合亚洲一区| 欧美性爱在线免费观看| 国产不卡在线看| 久久精品一区二区东京热| 无码网| 亚洲嫩模一区二区三区| 欧洲亚洲欧美国产日本高清| 99视频在线精品最新免费观看| 日本高清一区二区久久| 亚洲精品av无码喷奶水网站| 久久中文字幕av第二页| 天天躁夜夜躁天干天干2020| 久久AV秘?一区二区三区水生| 亚洲人成电影网站图片| 午夜福利视频在线观看| 精品人妻无码一区二区色欲产成人 |